新闻

您的位置:网站首页 > 新闻 > 新闻

EE8915

日期:2019-2-20 11:12:23

EE8915 measures reliably CO2 concentration in harsh environment and complies with the relevant railway standards. Active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independent of temperature, altitude or weather conditions.


The EE8915 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long-term stability. A multi-point CO2 and temperature adjustment procedure leads to excellent measurement accuracy over the entire temperature working range.

The innovative design enables the combination of short response time and high protection class. The CO2 measured data is available simultaneously as voltage and current output signal. The free EE-PCS Product Configuration Software facilitates the configuration and adjustment of the EE8915.

Due to the compliance with the tough railway standards, the EE8915 stands for excellent performance in any challenging process and climate control application.

Compliance with railway standards

  • EN50155:2007 - Electronic equipment used on rolling stock
  • EN50125-1:1999 - Environmental conditions for equipment - rolling stock and on-board equipment
  • EN50121-3-2:2006 - Electromagnetic compatibility - rolling stock
  • EN50121-1:2006 - Electromagnetic compatibility - general
  • EN61373:2011 - Rolling stock equipment - shock and vibration tests
  • EN45545-2 - Fire protection on railway vehicles
  • EN50306 - Railway rolling stock cables having special fire performance

Key Features

  • E+E dual wavelength NDIR working principle
  • T and p compensation with on-board sensors
  • IP65 protection class
  • Short response time
  • Excellent long-term stability
  • High insensitivity to pollution
  • Voltage and current outputs
  • User configurable and adjustable

Technical data

  • 0...2000 ppm 
    0...5000 ppm 
    0...10000 ppm

    MEASURING RANGE
  • < ± (50 ppm +2% of mv*)
    < ± (50 ppm +3% of mv*)
    < ± (100 ppm +5% of mv*)

    ACCURACY - *MV - MEASURED VALUE
  • 0-5 / 10V and 0 / 4-20mA

    OUTPUTS
  • 10-35 V DC

    SUPPLY